New Codes, Air Sealing and "Dynamic Walls"

Mar 8, 2017 3:46:55 PM By Stacy Fitzgerald-Redd
previous next

By Michael Schettine, Technical System Expert

New Housing Energy Requirements

The ante has been raised by states adopting the 2015 IECC energy code, and builders are scrambling to meet new requirements.

A large part of the new requirements involve envelope air leakage standards. Simply put, the house (envelope) air leakage, when tested at 50 Pa pressure differential, 'shall not exceed' 5 air changes/hour (ACH) in U.S. climate zones 1 and 2 (warmer areas) and 3 ACH in the remaining cooler zones 3-8. New homes must be tested, and those meeting the requirements will receive a “Certificate of Occupancy," which will be necessary for sale of the structure. Because the building must be largely completed before the testing can be performed, builders get one shot at achieving the air leakage standards, if the building doesn’t pass, costly rework and retesting must be done to ensure compliance with code.

Seal Those Gaps

It's clear that controlling air leakage is critical, but what is the most effective, economical method to employ? In a 2014 report, DOE findings “suggest that wall to foundation and wall to roof joints can be major contributors to air leakage,” and that these two joint areas accounted for nearly 50% of the overall leakage allowable. Additionally, these areas “are typically left unsealed by builders who are unfamiliar with air barrier systems.”

“If you drill it, you fill it” is the new mantra that sums up the importance of minimizing air leakage holes and gaps while construction is ongoing. Some builders are attempting to achieve the new standards using labor-intense methods such as caulking interior framing gaps, and/or taping and rolling exterior sheathing seams with specialty tapes. Taping of sheathing seams and water resistive barriers certainly helps to mitigate air intrusion, but it may also shift the air intrusion location to other unsealed areas.

The "Dynamic Wall"

Thermal Bypass.jpgWhen buildings are not sealed completely, air flow within the wall will result from the stack effect. The stack effect occurs when there are differences in temperature and moisture content of the inside and outside air. Warm air is more buoyant than cold air and will rise above the cooler air. In a house wall, a column of air is present and air buoyancy will result in air flow if the wall cavity isn't properly sealed.  Consider the house as a ‘whole-system’ during a wind load event.  Wind load against the foundation top (50 Pa = 20 MPH wind load) forces air currents upward and is caught where the siding overhang is lower than the sheathing, creating a small soffit-like trap, or worst, a U-channel (see figure) exactly where the lineal sheathing to frame  gaps are located. To compound the problem further, planned superior air flow, above the wall leakage point at the top plate, drafts air upward from soffit to ridge vent. This air flow results in a "dynamic" flow of air up through the wall cavity that is driven from below by wind load. The physical alignment of air buoyancy being pushed in from the bottom gaps and lifted from the top exit point can play a role in ice-damning on the roof because it is directly below the loss of semi-conditioned air and vapor passing through the wall cavity. This heat loss can be a contributing factor to ice damning and can occur 24/7, not only during the freeze/thaw cycle that occurs during daylight hours.  Keep in mind that the framing gaps can run nearly the entire length and width of a house, at both top and bottom plates, regardless of the nail pattern. The linked video (air flow video) demonstrates how virtually every wall built in America today functions at a 50 Pa pressure differential. 

Undeniably, unsealed sheathing to frame gaps (which, as mentioned above, can account for 50% of air leakage), when taken together, greatly contribute to the stack effect and energy loss in all climate conditions and offer a likely target for mitigation of the problem. 

The Solution

In the U.S. our climate zones vary greatly, and separate building zones have different approaches to preventing thermal loss from leakage. The most important factor in every building zone throughout the U.S. is that proper envelope sealing is necessary to increase energy performance and builders are requiring framers to play a larger role to ensure proper air sealing. Best practices reveal that sealing leaks during the framing stage is cost effective when labor is effectively utilized. In this era of skilled labor shortages, preventive methods must not only be effective and inexpensive but must also be easy to install. Builders need to consider all these aspects when selecting the best sealing system to implement.

In a subsequent blog, we will explore a new approach to continuous air sealing that has demonstrated great promise under ASTM E283 protocol1 testing by top laboratories and state agencies. This novel approach eliminates air leakage by more than 80% at 50 Pa in traditional frame building methods, mitigating air intrusion so optimum performance levels can be obtained.

About the author: Michael has more than forty years’ experience in home building, carpentry, and architectural restoration. He is currently president of, Schettine Associates Inc., which markets his patented AccuFrame Energy Seal, a construction-integrated gasket solution for Air Isolation Management-"AIM for Energy Performance"

1ASTM E283-04(2012), Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen, ASTM International, West Conshohocken, PA, 2012, www.astm.org

The views, opinions and positions expressed within these guest posts are those of the author alone and do not represent those of the North American Insulation Manufacturers Association (“NAIMA”). These blogs are provided to facilitate dialogue and exchange of views and information and does not imply NAIMA’s endorsement or sponsorship of any statement found therein.  The accuracy, completeness and validity of any statements made within these blog posts are not guaranteed. Reliance upon any statement, information, or opinion contained herein is to the users’ detriment and at their own risk.  NAIMA assumes no liability for any errors, omissions or representations. The copyright of this content belongs to the author and any liability with regards to infringement of intellectual property rights remains with them.

 